About 145,000 results
Open links in new tab
  1. Error Codes > Toshiba > e-Studio 2555C > Code C970

    Code: C970 Description: High-voltage transformer abnormality: Leakage of the main charger is detected. Causes: Remedy: Main charger Check if the main charger is installed securely. Spring of …

  2. Error Codes > Toshiba > e-Studio 2505 > Code C970

    Code: C970 Description: High-voltage transformer abnormality Causes: Remedy: 1. Is the main charger installed securely? 2. Check if the spring of high-voltage supply contact point is deformed. 3. Check if …

  3. Error Codes > Toshiba > e-Studio 2507 > Code C970

    Code: C970 Description: Process related service call High-voltage transformer abnormality: Leakage of the main charger is detected. Causes: Remedy: 1. Is the main charger installed securely? 2. Check if …

  4. Error Codes > Toshiba > e-Studio 355 > Code C970

    Code: C970 Description: High-voltage transformer abnormality: Leakage of the main charger is detected. Remedy: (1) Is the main charger installed securely? (2) Check if the spring of high-voltage …

  5. Error Codes > Toshiba > e-Studio 4508A > Code C970

    Code: C970 Description: High-voltage transformer abnormality Causes: Remedy: High-voltage section 1. Is the main charger installed securely? 2. Check if the spring of high-voltage supply contact point …

  6. Error Codes > Toshiba > e-Studio 257 > Code C970

    Code: C970 Description: High-voltage transformer abnormality: Leakage of the main charger is detected. Causes: Remedy: 2. Check if the spring of high-voltage supply contact point is deformed. …

  7. Error Codes > Toshiba > e-Studio 230 > Code C970

    Code: C970 Description: Process related service call High-voltage transformer abnormality: Leakage of the main charger is detected. Remedy: (1) Is the main charger installed securely? (2) Check if the …

  8. Error Codes > Toshiba > e-Studio 452 > page 1

    Code: C040 Description: PFP motor abnormality: The PFP motor is not rotating normally. Remedy: Is the PFP motor working? (Perform the output check in the test mode: 03-109/159) NO 1. Check if the …

  9. Error Codes > Toshiba > e-Studio 5540c > Code C970

    Code: C970 Description: High-voltage transformer abnormality: Leakage of the main charger is detected. Causes: Main charger Remedy: Main charger • Install check • Check if any foreign matter …

  10. Error Codes > Toshiba > e-Studio 3005AC > page 8

    If the same error occurs again, replace the LGC board. Code: C970 Description: High-voltage transformer abnormality: Leakage of the main charger is detected. Causes: Remedy: Main charger …